Siemens SIMATIC Wincc Runtime vulnerabilities
13 CVEs affecting Siemens SIMATIC Wincc Runtime, 0 known to be exploited (CISA KEV), with EPSS scores. Latest: CVE-2022-30694, published 2022-11-08.
More from Siemens.
Highest priority
Known exploited (CISA KEV) first, then by EPSS exploit probability.
- CVE-2011-3321, published 2011-09-16. High severity, CVSS 9.3. EPSS: 7.1% chance of exploitation in the next 30 days. Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a…
- CVE-2018-13812, published 2018-12-13. High severity, CVSS 7.5. EPSS: 3.6% chance of exploitation in the next 30 days. A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP…
- CVE-2019-6572, published 2019-05-14. Critical severity, CVSS 9.1. EPSS: 2.7% chance of exploitation in the next 30 days. A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI…
- CVE-2021-40142, published 2021-08-27. High severity, CVSS 7.5. EPSS: 2.6% chance of exploitation in the next 30 days. In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location…
- CVE-2017-6867, published 2017-05-11. Medium severity, CVSS 4.9. EPSS: 1.9% chance of exploitation in the next 30 days. A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal)…
- CVE-2019-6576, published 2019-05-14. Medium severity, CVSS 6.5. EPSS: 1.7% chance of exploitation in the next 30 days. A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI…
- CVE-2018-13814, published 2018-12-13. High severity, CVSS 8.8. EPSS: 1.7% chance of exploitation in the next 30 days. A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels…
- CVE-2018-13813, published 2018-12-13. High severity, CVSS 8.1. EPSS: 1.7% chance of exploitation in the next 30 days. A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP…
- CVE-2019-10935, published 2019-07-11. High severity, CVSS 7.2. EPSS: 1.3% chance of exploitation in the next 30 days. A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with…
- CVE-2019-10929, published 2019-08-13. Medium severity, CVSS 5.9. EPSS: 1% chance of exploitation in the next 30 days. A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU…
Latest
- CVE-2022-30694, published 2022-11-08. Medium severity, CVSS 6.5. EPSS: 0.3% chance of exploitation in the next 30 days. The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login…
- CVE-2019-6577, published 2019-05-14. Medium severity, CVSS 5.4. EPSS: 0.9% chance of exploitation in the next 30 days. A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI…