Siemens SIMATIC Winac Rtx Firmware vulnerabilities
4 CVEs affecting Siemens SIMATIC Winac Rtx Firmware, 0 known to be exploited (CISA KEV), with EPSS scores. Latest: CVE-2022-25622, published 2022-04-12.
More from Siemens.
Highest priority
Known exploited (CISA KEV) first, then by EPSS exploit probability.
- CVE-2019-6568, published 2019-04-17. High severity, CVSS 7.5. EPSS: 1.4% chance of exploitation in the next 30 days. The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the…
- CVE-2017-2680, published 2017-05-11. Medium severity, CVSS 6.5. EPSS: 1.1% chance of exploitation in the next 30 days. Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the…
- CVE-2017-2681, published 2017-05-11. Medium severity, CVSS 6.5. EPSS: 0.9% chance of exploitation in the next 30 days. Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to…
- CVE-2022-25622, published 2022-04-12. High severity, CVSS 7.5. EPSS: 0.9% chance of exploitation in the next 30 days. The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could…