- CVE-2022-36323, published 2022-08-10. Critical severity, CVSS 9.1. EPSS: 1.8% chance of exploitation in the next 30 days. Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
- CVE-2022-36324, published 2022-08-10. High severity, CVSS 7.5. EPSS: 1.7% chance of exploitation in the next 30 days. Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of…
- CVE-2020-25226, published 2021-01-12. Critical severity, CVSS 9.8. EPSS: 1.7% chance of exploitation in the next 30 days. A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions <…
- CVE-2020-15800, published 2021-01-12. Critical severity, CVSS 9.8. EPSS: 1.7% chance of exploitation in the next 30 days. A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions <…
- CVE-2020-28391, published 2021-01-12. Medium severity, CVSS 5.9. EPSS: 1.1% chance of exploitation in the next 30 days. A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions <…
- CVE-2020-15799, published 2021-01-12. Medium severity, CVSS 6.5. EPSS: 1.1% chance of exploitation in the next 30 days. A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions <…
- CVE-2022-36325, published 2022-08-10. Medium severity, CVSS 4.8. EPSS: 1% chance of exploitation in the next 30 days. Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code…