Tenda AC500 Firmware vulnerabilities
16 CVEs affecting Tenda AC500 Firmware, 0 known to be exploited (CISA KEV), with EPSS scores. Latest: CVE-2025-7586, published 2025-07-14.
More from Tenda.
Highest priority
Known exploited (CISA KEV) first, then by EPSS exploit probability.
- CVE-2023-25234, published 2023-02-27. Critical severity, CVSS 9.8. EPSS: 16.6% chance of exploitation in the next 30 days. Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface.
- CVE-2023-25235, published 2023-02-27. High severity, CVSS 7.5. EPSS: 11.1% chance of exploitation in the next 30 days. Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid.
- CVE-2024-3908, published 2024-04-17. Critical severity, CVSS 9.8. EPSS: 8.7% chance of exploitation in the next 30 days. A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac…
- CVE-2024-3907, published 2024-04-17. Critical severity, CVSS 9.8. EPSS: 1.9% chance of exploitation in the next 30 days. A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument…
- CVE-2024-3905, published 2024-04-17. High severity, CVSS 8.8. EPSS: 1.8% chance of exploitation in the next 30 days. A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the…
- CVE-2024-3910, published 2024-04-17. High severity, CVSS 8.8. EPSS: 1.7% chance of exploitation in the next 30 days. A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The…
- CVE-2024-3909, published 2024-04-17. Critical severity, CVSS 9.8. EPSS: 1.7% chance of exploitation in the next 30 days. A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the…
- CVE-2024-3906, published 2024-04-17. High severity, CVSS 8.8. EPSS: 1.7% chance of exploitation in the next 30 days. A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of…
- CVE-2025-7586, published 2025-07-14. High severity, CVSS 8.8. EPSS: 1.2% chance of exploitation in the next 30 days. A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation…
- CVE-2024-32314, published 2024-04-17. Low severity, CVSS 3.8. EPSS: 1% chance of exploitation in the next 30 days. Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
Latest
- CVE-2024-10280, published 2024-10-23. High severity, CVSS 7.5. EPSS: 0.8% chance of exploitation in the next 30 days. A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the…
- CVE-2024-32320, published 2024-04-17. Medium severity, CVSS 5.9. EPSS: 0.6% chance of exploitation in the next 30 days. Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.
- CVE-2024-32318, published 2024-04-17. Critical severity, CVSS 9.8. EPSS: 0.8% chance of exploitation in the next 30 days. Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function.
- CVE-2024-32316, published 2024-04-17. Medium severity, CVSS 6.5. EPSS: 0.4% chance of exploitation in the next 30 days. Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.
- CVE-2023-46060, published 2024-04-17. High severity, CVSS 7.5. EPSS: 0.8% chance of exploitation in the next 30 days. A Buffer Overflow vulnerability in Tenda AC500 v.2.0.1.9 allows a remote attacker to cause a denial of service via the port parameter at the goform/setVlanInfo component.