CVE-2025-3360: Red Hat Enterprise Linux 10
Low severity, CVSS 3.7. EPSS: 0.9% probability of exploitation activity in the next 30 days.
A flaw was found in GLib. An integer overflow and buffer under-read occur when parsing a long invalid ISO 8601 timestamp with the g_date_time_new_from_iso8601() function.
What to do
The record states a fixed version for each range of affected versions. Update to the one for the range your version is in: a later release on another branch may not have the fix.
- Siemens Ruggedcom RST2428P, before V3.3: fixed in V3.3
- Siemens Scalance Xc-300/xr-300/xc-400/xr-500wg/xr-500 Family, before V3.3: fixed in V3.3
- Siemens Scalance XCH328, before V3.3: fixed in V3.3
- Siemens Scalance XCM324, before V3.3: fixed in V3.3
- Siemens Scalance XCM328, before V3.3: fixed in V3.3
- Siemens Scalance XCM332, before V3.3: fixed in V3.3
- Siemens Scalance XRH334 24 V Dc, 8xfo, Cc, before V3.3: fixed in V3.3
- Siemens Scalance XRM334 230 V Ac, 12xfo, before V3.3: fixed in V3.3
- Siemens Scalance XRM334 230 V Ac, 8xfo, before V3.3: fixed in V3.3
- Siemens Scalance XRM334 230v Ac, 2x10g, 24xsfp, 8xsfp+, before V3.3: fixed in V3.3
- and 9 more
Affected products
- Red Hat Red Hat Enterprise Linux 10
- Red Hat Red Hat Enterprise Linux 6
- Red Hat Red Hat Enterprise Linux 7
- Red Hat Red Hat Enterprise Linux 8
- Red Hat Red Hat Enterprise Linux 9
- Red Hat Red Hat Openshift Ai Rhoai
- Siemens Ruggedcom RST2428P: before V3.3 (fixed in V3.3)
- Siemens Scalance Xc-300/xr-300/xc-400/xr-500wg/xr-500 Family: before V3.3 (fixed in V3.3)
- Siemens Scalance XCH328: before V3.3 (fixed in V3.3)
- Siemens Scalance XCM324: before V3.3 (fixed in V3.3)
- Siemens Scalance XCM328: before V3.3 (fixed in V3.3)
- Siemens Scalance XCM332: before V3.3 (fixed in V3.3)
- Siemens Scalance XRH334 24 V Dc, 8xfo, Cc: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 230 V Ac, 12xfo: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 230 V Ac, 8xfo: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 230v Ac, 2x10g, 24xsfp, 8xsfp+: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 24 V Dc, 12xfo: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 24 V Dc, 8xfo: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 24v Dc, 2x10g, 24xsfp, 8xsfp+: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 2x230 V Ac, 12xfo: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 2x230 V Ac, 8xfo: before V3.3 (fixed in V3.3)
- Siemens Scalance XRM334 2x230v Ac, 2x10g, 24xsfp, 8xsfp+: before V3.3 (fixed in V3.3)
- Siemens SIMATIC s7-1500 CPU 1518-4 Pn/dp Mfp: from V3.1.0, before V3.1.5 (fixed in V3.1.5)
- Siemens SIMATIC s7-1500 CPU 1518f-4 Pn/dp Mfp: from V3.1.0, before V3.1.5 (fixed in V3.1.5)
- Siemens Siplus s7-1500 CPU 1518-4 Pn/dp Mfp: from V3.1.0, before V3.1.5 (fixed in V3.1.5)
Published 2025-04-07. Last modified 2026-11-25.