CVE-2025-27438: Siemens Teamcenter Visualization
High severity, CVSS 7.8. EPSS: 0.3% probability of exploitation activity in the next 30 days.
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
What to do
The record states a fixed version for each range of affected versions. Update to the one for the range your version is in: a later release on another branch may not have the fix.
- Siemens Teamcenter Visualization, from 14.3, before 14.3.0.13: fixed in 14.3.0.13
- Siemens Teamcenter Visualization, from 2312.0, before 2312.0009: fixed in 2312.0009
- Siemens Teamcenter Visualization, from 2406.0, before 2406.0007: fixed in 2406.0007
- Siemens Teamcenter Visualization, from 2412.0, before 2412.0002: fixed in 2412.0002
- Siemens Tecnomatix Plant Simulation, from 2404.0, before 2404.0010: fixed in 2404.0010
- Siemens Tecnomatix Plant Simulation, from 2412.0, before 2412.0002: fixed in 2412.0002
Affected products
- Siemens Teamcenter Visualization: from 14.3, before 14.3.0.13 (fixed in 14.3.0.13); from 2312.0, before 2312.0009 (fixed in 2312.0009); from 2406.0, before 2406.0007 (fixed in 2406.0007); from 2412.0, before 2412.0002 (fixed in 2412.0002)
- Siemens Tecnomatix Plant Simulation: from 2302.0, up to and including 2302.0021; from 2404.0, before 2404.0010 (fixed in 2404.0010); from 2412.0, before 2412.0002 (fixed in 2412.0002)
Published 2025-03-11. Last modified 2026-06-17.