CVE-2025-24811: Siemens SIMATIC s7-1200 CPU 1211c Ac/dc/rly
High severity, CVSS 7.5. EPSS: 0.6% chance of exploitation in the next 30 days.
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0). Affected devices do not process correctly certain special crafted packets sent to port 80/tcp, which could allow an unauthenticated attacker to cause a denial of service in the device.
Affected products
- Siemens SIMATIC s7-1200 CPU 1211c Ac/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1211c Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1211c Dc/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1212c Ac/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1212c Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1212c Dc/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1212fc Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1212fc Dc/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1214c Ac/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1214c Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1214c Dc/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1214fc Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1214fc Dc/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1215c Ac/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1215c Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1215c Dc/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1215fc Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1215fc Dc/dc/rly: before V4.7 (fixed in V4.7)
- Siemens SIMATIC s7-1200 CPU 1217c Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens Siplus s7-1200 CPU 1212 Ac/dc/rly: before V4.7 (fixed in V4.7)
- Siemens Siplus s7-1200 CPU 1212 Dc/dc/rly: before V4.7 (fixed in V4.7)
- Siemens Siplus s7-1200 CPU 1212c Dc/dc/dc: before V4.7 (fixed in V4.7)
- Siemens Siplus s7-1200 CPU 1212c Dc/dc/dc Rail: before V4.7 (fixed in V4.7)
- Siemens Siplus s7-1200 CPU 1214 Ac/dc/rly: before V4.7 (fixed in V4.7)
- Siemens Siplus s7-1200 CPU 1214 Dc/dc/dc: before V4.7 (fixed in V4.7)
- and 9 more
Published 2025-02-11. Last modified 2026-06-17.