CVE-2024-49704: Siemens Comos v10.3
Medium severity, CVSS 5.5. EPSS: 0.2% chance of exploitation in the next 30 days.
A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The Generic Data Mapper, the Engineering Adapter, and the Engineering Interface improperly handle XML External Entity (XXE) entries when parsing configuration and mapping files. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by persuading a user to use a maliciously crafted configuration or mapping file in one of the affected components.
Affected products
- Siemens Comos v10.3: before V10.3.3.5.8 (fixed in V10.3.3.5.8)
- Siemens Comos v10.4.0: any version
- Siemens Comos v10.4.1: any version
- Siemens Comos v10.4.2: any version
- Siemens Comos v10.4.3: before V10.4.3.0.47 (fixed in V10.4.3.0.47)
- Siemens Comos v10.4.4: before V10.4.4.2 (fixed in V10.4.4.2)
- Siemens Comos v10.4.4.1: before V10.4.4.1.21 (fixed in V10.4.4.1.21)
Published 2024-12-10. Last modified 2026-06-17.