CVE-2024-41977: Siemens Ruggedcom RM1224 lte(4g) Eu Firmware

High severity, CVSS 8.0. EPSS: 0.4% chance of exploitation in the next 30 days.

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices do not properly enforce isolation between user sessions in their web server component. This could allow an authenticated remote attacker to escalate their privileges on the devices.

Affected products

  • Siemens Ruggedcom RM1224 lte(4g) Eu Firmware: before 8.1 (fixed in 8.1)
  • Siemens Ruggedcom RM1224 lte(4g) Nam Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m804pb Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m812-1 (annex A) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m812-1 (annex B) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m816-1 (annex A) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m816-1 (annex B) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m826-2 Shdsl-Router Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m874-2 Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m874-3 3g-Router (cn) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m874-3 Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m876-3 (rok) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m876-3 Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m876-4 (eu) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m876-4 (nam) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance m876-4 Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance MUM853-1 (a1) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance MUM853-1 (b1) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance MUM853-1 (eu) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance MUM856-1 (a1) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance MUM856-1 (b1) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance MUM856-1 (cn) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance MUM856-1 (eu) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance MUM856-1 (row) Firmware: before 8.1 (fixed in 8.1)
  • Siemens Scalance s615 Eec Lan-Router Firmware: before 8.1 (fixed in 8.1)
  • and 1 more

Published 2024-08-13. Last modified 2026-06-17.