CVE-2024-32636: Siemens JT2GO

High severity, CVSS 7.8. EPSS: 0.3% probability of exploitation activity in the next 30 days.

A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.

What to do

The record states a fixed version for each range of affected versions. Update to the one for the range your version is in: a later release on another branch may not have the fix.

  • Siemens JT2GO, from 2312.0, before 2312.0005: fixed in 2312.0005
  • Siemens Parasolid, from 35.1, before 35.1.256: fixed in 35.1.256
  • Siemens Parasolid, from 36.0, before 36.0.208: fixed in 36.0.208
  • Siemens Parasolid, from 36.1, before 36.1.173: fixed in 36.1.173
  • Siemens Teamcenter Visualization, from 14.2, before 14.2.0.12: fixed in 14.2.0.12
  • Siemens Teamcenter Visualization, from 14.3, before 14.3.0.10: fixed in 14.3.0.10
  • Siemens Teamcenter Visualization, from 2312.0, before 2312.0005: fixed in 2312.0005

Affected products

  • Siemens JT2GO: from 2312.0, before 2312.0005 (fixed in 2312.0005)
  • Siemens Parasolid: from 35.1, before 35.1.256 (fixed in 35.1.256); from 36.0, before 36.0.208 (fixed in 36.0.208); from 36.1, before 36.1.173 (fixed in 36.1.173)
  • Siemens Teamcenter Visualization: from 14.2, before 14.2.0.12 (fixed in 14.2.0.12); from 14.3, before 14.3.0.10 (fixed in 14.3.0.10); from 2312.0, before 2312.0005 (fixed in 2312.0005)

Published 2024-05-14. Last modified 2026-06-17.