CVE-2021-43336: Opendesign Drawings Software Development Kit
High severity, CVSS 7.8. EPSS: 1.7% probability of exploitation activity in the next 30 days.
An Out-of-Bounds Write vulnerability exists when reading a DXF or DWG file using Open Design Alliance Drawings SDK before 2022.11. The specific issue exists within the parsing of DXF and DWG files. Crafted data in a DXF or DWG file (an invalid number of properties) can trigger a write operation past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.
What to do
The record states a fixed version for each range of affected versions. Update to the one for the range your version is in: a later release on another branch may not have the fix.
- Opendesign Drawings Software Development Kit, before 2022.11: fixed in 2022.11
- Siemens Teamcenter Visualization, from 12.4.0, before 12.4.0.13: fixed in 12.4.0.13
- Siemens Teamcenter Visualization, from 13.2.0, before 13.3.0.1: fixed in 13.3.0.1
Affected products
- Opendesign Drawings Software Development Kit: before 2022.11 (fixed in 2022.11)
- Siemens JT2GO: any version
- Siemens Solid Edge: version se2022 only
- Siemens Teamcenter Visualization: from 12.4.0, before 12.4.0.13 (fixed in 12.4.0.13); from 13.2.0, before 13.3.0.1 (fixed in 13.3.0.1); version 13.1.0 only
Published 2021-11-14. Last modified 2026-06-17.