CVE-2021-22681: Rockwell Multiple Products Insufficient Protected Credentials Vulnerability
Critical severity, CVSS 9.8. Actively exploited: in CISA KEV since 2026-03-05. EPSS: 64% probability of exploitation activity in the next 30 days.
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
What to do
CISA's required action (US federal agencies, by 2026-03-26): Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
No fixed version is stated in NVD's or the CNA's structured data. Check the vendor's advisory among the references.
Affected products
- Rockwellautomation Factorytalk Services Platform: from 2.10
- Rockwellautomation Rslogix 5000: from 16, up to and including 20
- Rockwellautomation Studio 5000 Logix Designer: from 21.0
Published 2021-03-03. Last modified 2026-06-17.