CVE-2019-12260: Belden Garrettcom Magnum DX940E Firmware

Critical severity, CVSS 9.8. EPSS: 20% probability of exploitation activity in the next 30 days.

Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option.

What to do

The record states a fixed version for each range of affected versions. Update to the one for the range your version is in: a later release on another branch may not have the fix.

  • Siemens Power Meter 9410 Firmware, before 2.2.1: fixed in 2.2.1
  • Siemens Ruggedcom WIN7000 Firmware, before bs5.2.461.17: fixed in bs5.2.461.17
  • Siemens Ruggedcom WIN7018 Firmware, before bs5.2.461.17: fixed in bs5.2.461.17
  • Siemens Ruggedcom WIN7025 Firmware, before bs5.2.461.17: fixed in bs5.2.461.17
  • Siemens Ruggedcom WIN7200 Firmware, before bs5.2.461.17: fixed in bs5.2.461.17
  • Siemens Siprotec 5 Firmware, before 7.59: fixed in 7.59
  • Siemens Siprotec 5 Firmware, before 7.91: fixed in 7.91
  • Windriver Vxworks, from 6.5, before 6.9.4.12: fixed in 6.9.4.12

Affected products

Published 2019-08-09. Last modified 2026-06-17.